Isolator, Gang Operated

Download sample:

SKYPE:+8613736310909

Wechat:+8613736310909

WhatsAPP:+8613736310909

Viber:+8613736310909

E-mail:xk@cnxiya.com

QQ:195457709

wechat:xiyapower

Dingtalk:+8613736310909

  • Product Details
Basic Info
  • Model NO.: IST-11/630

  • Structure: Three-column Disconnector

  • Operation: Manual

  • Movement Mode: Horizontal Rotary Type

  • Grounding: Single Ground

  • Run: Turn the Horizontal

  • Structure of Operating: Manual

  • Brand: XIKAI

  • 24: Kv

  • Trademark: OEI Power

  • Origin: China Zhejiang

  • Type: High-voltage

  • Installation: Outdoor High-voltage

  • Grounding Mode: Grounding

  • Number of Poles: Three Pole

  • Series: Three

  • Common Model: Ist

  • Certification: IEC IEEE

  • 12: Kv

  • 36: Kv

  • Specification: IEC IEEE


    These disconnectors are , no load switching devices
    which physically isolate the lines. They are designed for
    horizontal outdoor application and can also be designed
    for vertical installation. For earthing and closing of
    switchyard portions of the installation, the earthing
    switches are provided on disconnector. If required.

    The following documents were referred to during the preparation of this specification. In case of conflict, the provisions of this specification shall take precedence.
    IEC 129:1975: Alternating Current Disconnectors (Isolators) and Earthing Switches
    IEC 60694:2002: Common Specifications for High Voltage Switchgear and Controlgear
    BS 729: Hot dip galvanized coating on iron and steel articles
    IEC62271-102
    Isolator (Disconnector) - a mechanical switching device which provides, in the open position, an isolating distance in accordance with Electrical Safety requirements.

    SERVICE CONDITIONS
    The isolator shall be suitable for continuous operation outdoors in tropical areas at altitudes of up to 2200m above sea level, humidities of up to 90%, average ambient temperature of +30篊 with a minimum of -1篊 and a maximum of +40篊 and heavy saline conditions along the coast.

    4.2. DESIGN AND CONSTRUCTION
    4.2.1 The Isolator, Solid Link shall be designed and constructed in accordance with IEC 129 and IEC 60694.
    4.2.2 The isolating link shall be of the vertical opening, designed for single phase manual operation. It shall be easily removed and replaced by using a portable operating rod.
    4.2.3 The isolating link shall incorporate double porcelain insulators to suit voltage requirements and mounted on hot dipped galvanised steel under base suitable for vertical mounting.
    4.2.4 The isolating link shall be arranged so that each unit is mounted independently on an angle bracket. It shall be supplied complete with the angle bracket and accessories suitable for mounting on 'U' type steel channel. The drawings to be submitted shall indicate all the applicable mounting positions.
    4.2.5 The isolator shall be designed such that in fully open position, it shall provide adequate electrical isolation between the contacts on each phase. It shall conform to the requirement as single point isolation for safety.
    4.2.6 All steel parts shall be hot dip galvanized to BS 729. The minimum coating of galvanizing required is 80 microns.
    4.2.7 The solid link shall be removable from the mounting by use of operating rod.
    4.2.8 All current carrying parts of the isolator shall be made of high conductivity material.
    4.2.9 The isolator shall be fitted with clamp connectors for Aluminium (ACSR) conductor of Aluminium (ACSR)conductor of up to 18.2mm diameter.

    The rating of the complete isolator shall be as follows: -
    Rated voltage
    36 kV
    Rated frequency
    50 Hz
    Rated lightning impulse withstand voltage
    200 kV
    Rated power frequency withstand voltage, dry
    95 kV
    Rated normal current
    400 Amps
    Rated short time withstand current for 3 sec, min.
    18.0 kA
    Minimum creepage distance of insulators
    900 mm

     SOLID LINKS 11KV
     
    N/ODETAIL
    DATA
    1Description
    Solid link assembly complete with link
    rated at 200A and mounting bracket to PIESA 002.(See Figure 1  to Figure 12 below)
    2System conditions of service
     
     
     
    a) nominal Voltage (Un) r.m.s
     
     
     
     
    kV
     
     
     
     
    11
    b) maximum system voltage (Um) r.m.sKV12
    c) earthing
    Effective & non effective
    d) FrequencyHz50
    3Site conditions of service
    a) altitude
     
    m
     
    1400
    b) Operating Ambient temperature-1 to 40
    c) Humidity%85
    4Rating

    a) Nominal voltagekV11
    b) Rated currentSolid link 
    A
     
    200
     
    Cut out base
     
    A
     
    200
    5Electrical components

    a) Insulator material specification
    Porcelain
    Dielectric strength

    Lightning  impulse withstand (1.2/50)kV95
    Power frequency wet withstand voltage
    r.m.s
    kV28
    6Specific creepage distancemm/kV25

    7General information to be provided
    with bid:
    Drawings and brochures showing outline and general arrangement
     
     
     
     
    Yes/No
     
     
     
     
    Yes

    b) Detailed drawings of all items
    showing critical tolerances to be provided with bid
    Yes/NoYes
    8Previous Type test report/certificate on
    complete solid link assembly to be provided with bid
     
    Yes/No
     
    Yes
    10Routine tests (acceptance tests on
    sample
    Product) to be provided on delivery
    Yes/NoYes
    11Applicable standard
    PIESA 002
    12Other applicable standards
    NRS 035
    SABS IEC 60282-2
    SABS IEC 60186
    BS 137 part 2

    TRI-LINKS
     
    Lot 3-(a) 11kV with interrupters
     
    N/ODETAIL
    DATA
    1TYPE
    11kV pre-assembled gang
    operated overhead line load break switch complete with expulsioninterrupters
    2Mounting configuration
    Horizontal
    3Mode of operation
    Manually operated pole
    mounted linking rod and handle withlocking facilities

    a) nominal Voltage (Un) r.m.skV11
    b) maximum voltage (Um) r.m.sKV12
    c) earthing
    Effective & non effective
    d) FrequencyHz50
    e) rated currentAmp400
    f) Fault closing capacitykA12.5
    4Site conditions of service
    a) altitude
     
    metres
     
    1400
    b) Operating Ambient temperature 
     
    -1 to +40
    c) Relative humidity%85
    5Electrical components

    a) Insulator material specification
    High Temperature Vulcanised
    Silicon rubber
    b) Cross arm and operating controls materials
    Hot dip galvanized steel to
    SAN760
    Dielectric strength

    Lightning  impulse withstand (1.2/50)kV95


    Power frequency wet withstand voltage r.m.sKV28

    Short time current rating -1seckA12.5
    6creepage distancemm/kV25
    7General information to be provided with bid:
    Drawings and brochures showing
    Outline and general arrangement
     
     
     
    Yes/No
     
     
     
    Yes
    8Previous Type test report/certificate on complete
    assembly to be provided with bid
    Yes/NoYes.
    9Routine tests (acceptance tests on sample
     
    Product) to be provided on delivery.
    Yes/NoYes
    10Applicable standards
    IEC62271

    FURTHER REQUIREMENTS:
    Water shall not be able to accumulate on any part of the equipment nor shall any feature introduce moisture into any component.
    The design shall incorporate all reasonable precautions and provisions for the safety of personnel concerned with the operation and maintenance of the same.
    The current path shall be such that load current shall only flow through high conductive materials such as copper and its alloys.Load current shall not be permitted to flow through ferrous components, springs, or spring-loaded mechanisms.
    All load current paths shall be so designed that the relevant parts of the switch are capable of carrying the specified rated current without exceeding the permitted temperature rise.
     
    SUPPLIMENTARY NOTES
    Suppliers should give sufficient information including drawings (which must be brief, clear and to the point) on how their switch designs addresses these requirements. Further, Suppliers may offer better alternatives that are of cost benefits to customer, It istherefore imperative that schedule "B" is completed by the tenderer. Any deviations/modifications/alternatives specification must be listed in schedule "C.
    33kV with interrupters
    N/ODETAIL
    DATA
    1TYPE
    33kV pre-assembled gang
    operated overhead line load break switch complete with expulsioninterrupters
    2Mounting configuration
    Horizontal
    3Mode of operation
    Manually operated pole
    mounted linking rod and handle withlocking facilities

    a) nominal Voltage (Un) r.m.skV33
    b) maximum voltage (Um) r.m.sKV36
    c) earthing
    Effective & non effective
    d) FrequencyHz50
    e) rated currentAmp200
    f) Fault closing capacitykA12.5
    4Site conditions of service
    a) altitude
     
    metres
     
    1400
    b) Operating Ambient temperature 
     
    -1 to +40
    c) Relative humidity%85
    5Electrical components

    a) Insulator material specification
    High Temperature Vulcanised
    Silicon rubber
    b) Cross arm and operating controls materials
    Hot dip galvanized steel to
    SAN760
    Dielectric strength

    Lightning  impulse withstand (1.2/50)kV170
    Power frequency wet withstand voltage r.m.sKV70

    Short time current rating -1seckA12.5
    6creepage distancemm/kV25
    7General information to be provided with bid:



    Drawings and brochures showing
    Outline and general arrangement
     
    Yes/No
     
    Yes
    8Previous Type test report/certificate on complete
    assembly to be provided with bid
    Yes/NoYes
    9Routine tests (acceptance tests on sample
     
    Product) to be provided on delivery
    Yes/NoYes
    10Applicable standards
    IEC62271

    FURTHER REQUIREMENTS:
    Water shall not be able to accumulate on any part of the equipment nor shall any feature introduce moisture into any component.
    The design shall incorporate all reasonable precautions and provisions for the safety of personnel concerned with the operation and maintenance of the same.
    The current path shall be such that load current shall only flow through high conductive materials such as copper and its alloys.Load current shall not be permitted to flow through ferrous components, springs, or spring-loaded mechanisms.
    All load current paths shall be so designed that the relevant parts of the switch are capable of carrying the specified rated current without exceeding the permitted temperature rise.
    SUPPLIMENTARY NOTES
    Suppliers should give sufficient information including drawings (which must be brief, clear and to the point) on how their switch designs addresses these requirements. Further, Suppliers may offer better alternatives that are of cost benefits to custoemr.
    11kV without interrupters
    N/ODETAIL
    DATA
    1TYPE
    11kV pre-assembled gang
    operated overhead line switch withoutexpulsion interrupters (non-load breakswitch)
    2Mounting configuration
    Horizontal
    3Mode of operation
    Manually operated pole
    mounted linking rod and handle withlocking facilities

    a) nominal Voltage (Un) r.m.skV11
    b) maximum voltage (Um) r.m.sKV12
    c) earthing
    Effective & non effective
    d) FrequencyHz50
    e) rated currentAmp400
    4Site conditions of service
    a) altitude
     
    metres
     
    1400
    b) Operating Ambient temperature 
     
    -1 to +40
    c) Relative humidity%85
    5Electrical components

    a) Insulator material specification
    High Temperature Vulcanised
    Silicon rubber
    b) Cross arm and operating controls materials
    Hot dip galvanized steel to
    SAN760
    Dielectric strength

    Lightning  impulse withstand (1.2/50)kV95
    Power frequency wet withstand voltage r.m.sKV28

    Short time current rating -1seckA12.5
    6creepage distancemm/kV25
    7General information to be provided with bid:



    Drawing and brochures showing
    Outline and general arrangement
     
    Yes/No
     
    Yes
    8Previous Type test report/certificate on complete
    assembly to be provided with bid
    Yes/NoYes
    9Routine tests (acceptance tests on sample
     
    Product) to be provided on delivery
    Yes/NoYes
    10Applicable standards
    IEC62271

    FURTHER REQUIREMENTS:
    Water shall not be able to accumulate on any part of the equipment nor shall any feature introduce moisture into any component.
    The design shall incorporate all reasonable precautions and provisions for the safety of personnel concerned with the operation and maintenance of the same.
    The current path shall be such that load current shall only flow through high conductive materials such as copper and its alloys.Load current shall not be permitted to flow through ferrous components, springs, or spring-loaded mechanisms.
    All load current paths shall be so designed that the relevant parts of the switch are capable of carrying the specified rated current without exceeding the permitted temperature rise.
    SUPPLIMENTARY NOTES
    Suppliers should give sufficient information including drawings (which must be brief, clear and to the point) on how their switch designs addresses these requirements. Further, Suppliers may offer better alternatives that are of cost benefits to
    33kV without interrupters
    N/ODETAIL
    DATA
    1TYPE
    33kV pre-assembled gang
    operated overhead line switch withoutexpulsion interrupters (non-load breakswitch)
    2Mounting configuration
    Horizontal
    3Mode of operation
    Manually operated pole
    mounted linking rod and handle withlocking facilities

    a) nominal Voltage (Un) r.m.skV33
    b) maximum voltage (Um) r.m.sKV36
    c) earthing
    Effective & non effective
    d) FrequencyHz50
    e) rated currentAmp200
    4Site conditions of service
    a) altitude
     
    metres
     
    1400
    b) Operating Ambient temperature 
     
    -1 to +40
    c) Relative humidity%85
    5Electrical components

    a) Insulator material specification
    High Temperature Vulcanised
    Silicon rubber
    b) Cross arm and operating controls materials
    Hot dip galvanized steel to
    SAN760
    Dielectric strength

    Lightning  impulse withstand (1.2/50)kV170
    Power frequency wet withstand voltage r.m.sKV70

    Short time current rating -1seckA12.5
    6creepage distancemm/kV25
    7General information to be provided with bid:



    Drawing and brochures showing
    Outline and general arrangement
     
    Yes/No
     
    Yes
    8Previous Type test report/certificate on complete
    assembly to be provided with bid
    Yes/NoYes
    9Routine tests (acceptance tests on sample
     
    Product) to be provided on delivery
    Yes/NoYes
    10Applicable standards
    IEC62271


    FURTHER REQUIREMENTS:
    Water shall not be able to accumulate on any part of the equipment nor shall any feature introduce moisture into any component.
    The design shall incorporate all reasonable precautions and provisions for the safety of personnel concerned with the operation and maintenance of the same.
    The current path shall be such that load current shall only flow through high conductive materials such as copper and its alloys.Load current shall not be permitted to flow through ferrous components, springs, or spring-loaded mechanisms.
    All load current paths shall be so designed that the relevant parts of the switch are capable of carrying the specified rated current without exceeding the permitted temperature rise.
    SUPPLIMENTARY NOTES
    Suppliers should give sufficient information including drawings (which must be brief, clear and to the point) on how their switch designs addresses these requirements. Further, Suppliers may offer better alternatives that are of cost benefits to.